DNA clean up kit · No centrifuge

No-Centrifuge DNA Clean Up Kit

48 pre-filled bead tubes in 8-tube strips. Vortex to mix, slide to the magnet to separate — 2–3 minutes of hands-on time.

Hands-on
2–3 min
Sample
≤ 50 µl
Yield
≤ 5 µg
Choose quantity
- +
$1.46 / rxn
  • Ships within 1 business day from Southern California — at room temperature, no dry ice
  • Card checkout via Stripe, or pay by purchase order
  • Made by us in Southern California — every batch tested in real research

Vortex and magnets instead of spinning

By eliminating repetitive tube transfers between racks and centrifuges, you dramatically accelerate your workflow.

  • Single-rack procedure: pair with our Dual-Zone Magnetic Stand to load, wash and elute without moving samples between racks.
  • Ready to use: 48 tubes pre-filled with magnetic beads and binding buffer – just add your DNA.
  • Convenient format: 8-tube strips with attached caps.
  • Flexible capacity: each tube takes up to 50 µl of sample.
  • Zero waste: strips snap apart to process fewer than 8 samples at a time.
  • High yield: up to 5 µg of purified DNA.
  • Multichannel-friendly: optimized for 8-channel pipettes.

Specifications

Reactions48
Format6 × 8-tube strips with attached caps
Sample volumeUp to 50 µl per tube
DNA yieldUp to 5 µg
Hands-on time2–3 min
CentrifugeNot needed
StorageRoom temperature
Kit contents48 tubes pre-filled with beads and binding buffer; Wash Buffer concentrate (WB-50, add 40 ml absolute ethanol); Elution Buffer, 10 ml (EB-10)

Quick protocol

Every step happens in one rack. For the best results, use the Dual-Zone Magnetic Stand.

  1. 01 · Bind

    Add up to 50 µl of DNA sample. Vortex on the non-magnetic zone and incubate 1–2 min.

  2. 02 · Clear

    Slide to the magnetic zone – beads collect instantly. Aspirate the liquid.

  3. 03 · Wash ×2

    150 µl Wash Buffer: resuspend off the magnet, collect on it, remove.

  4. 04 · Dry & elute

    Air-dry a few minutes, then elute in 20–50 µl Elution Buffer or water.

Important: add 40 ml of absolute ethanol to the Wash Buffer concentrate before first use.

Full protocol with tips

Pro Tip: Shipping, handling and mixing may cause beads to stick to tube caps. A brief vortex while on the magnetic stand quickly pulls all beads back into solution.

  1. Add Sample: Carefully open the tubes to prevent splashing. Add up to 50 µl of your DNA sample (e.g., PCR product).
  2. Mix: Move the tubes to the non-magnetic zone and vortex briefly to fully resuspend the beads.
  3. Incubate: Allow 1–2 minutes for optimal binding. Periodically vortex or invert the tubes to keep the beads in suspension.
  4. Clear Supernatant: Transfer tubes to the magnetic zone for instant bead collection. Vortex briefly while on the magnets to clear the tube walls and caps, then aspirate the liquid. Note: Residual liquid may adhere to the caps. If you choose not to remove it, simply perform one additional wash (3 total washes) to guarantee purity.
  5. Wash 1: Add 150 µl of Wash Buffer. Move to the non-magnetic zone and vortex to resuspend. Return to the magnets, vortex briefly to collect, and remove the supernatant.
  6. Wash 2: Repeat the wash step. Add 150 µl of Wash Buffer, resuspend on the non-magnetic zone, collect on the magnets, and completely remove all remaining liquid. We recommend a minimum of two washes. If residual droplet removal from the caps was skipped in Step 4, proceed with a third wash.
  7. Drying: Leave the tubes open for a few minutes. Avoid over-drying; proceed as soon as visible droplets vanish from the walls. Speed Tip: Place the open tubes in a thermal cycler at 55°C to complete drying in just 1–2 minutes.
  8. Elution: Add your desired volume of Elution Buffer (10 mM Tris, 0.1 mM EDTA) or molecular-grade water – typically 20 to 50 µl. Vortex on the non-magnetic zone to resuspend. Incubate for 1–2 minutes to elute. If cap droplets were not cleared prior to drying, they may contain trace wash buffer. To prevent sample contamination, mix gently by pipetting up and down instead of vortexing.
  9. Final Collection: Return the tubes to the magnetic zone and pipette out your purified, high-quality DNA.

Documents

Safety Data Sheet (SDS) and Certificate of Analysis (CoA) are available on request: email contact@longstridebio.com.

Complete the workflow

The stand the protocol is built around: magnetic and non-magnetic zones in one rack.

Cat # Product Size Price Quantity
MRRM-48 Dual-Zone Magnetic Stand, PCR & deep well 48 wells $75
- +